Reliable Power Level Monitoring and Control for Nuclear Power Plants

Is it time to modernize your aged or obsolete nuclear instrumentation systems to support life extension?

Are your current systems unreliable and noisy, resulting in extended outages to troubleshoot and repair or replace failures?

The Paragon CoreVision Neutron Flux Monitoring System is a complete line of neutron flux monitoring system products to help nuclear power plants solve these problems.

Source Range Neutron Monitor

InputsRatings
AC Input Power230 or 120 VAC, Single Phase, ±10%, 50/60 Hz, <150 VA
OR
DC Input Power125 VDC, ±10%, < 150 Watts
Preamplifier Input Impedance50Ω typical, other values available upon request
Detector Input ConnectorsSHV typical, other input connection types upon request
Note 1: Post-accident monitoring (PAM) functionality requires US NRC RG 1.97 qualified detector.
OutputsRatingsAccuracy
Pulse Level5 VDC TTL 0 to 106 CPS±1% Full Scale
Log Count Rate Level0 to 10 VDC or 4 to 20 mA 0.1 to 1E+6 CPS±2% Full Scale
LCR Rate (Doubling Time)0 to 10 VDC or 4 to 20 mA -30 … ∞ … 3 seconds±1% Full Scale
Ion Chamber High Voltage100 to 3000 VDC, 10 W Max±5% Full Scale
Front Panel Isolated BNC Multiple Signal Selections0 to 10 VDC1% Full Scale
LCR Level Trip 1*Form C Relay, 125VDC / 100mA Max
LCR Level Trip 2*
LCR Rate Trip 1*
LCR Rate Trip 2*
Channel-In-Test
Non-Op
Door Open
Audible Count Rate, Manual Divider Selectable (1, 10, 100, 1k, 10k)90 dB at 30 cm0–55 CPS
*Increasing or decreasing slope selectable.
Enclosure Specification
Size (L x W x H)24″ x 16″ x 10″ (61 cm x 41 cm x 26 cm)
Weight50 lbs (23 kg)
MaterialStainless Steel
MountingWall Mount (4 Tabs)
SecurityLocking Door
Temperature Range32°F to 140°F (0°C to +60°C)
Relative Humidity10% to 95%, non-condensing
QualificationSafety Class 1E

Fully Analog Electronics
Safety Class 1E

  • Used during reactor start-up and post-accident monitoring (PAM) utilizing an ion chamber such as a BF3, B-10, He3, or fission chamber.
  • The unit features a selectable internal test function generator and multiple trip functions for each flux measurement output.
  • The unit also features two multi-digit displays and two vertical bar graphs for easy identification of displayed variables.
  • Displays and operator controls are designed to comply with NUREG-0700.


Wide Range Neutron Monitor

InputsRatings
AC Input Power230 or 120 VAC, Single Phase, ±10%, 50/60 Hz, <150 VA
OR
DC Input Power125 VDC, ±10%, < 150 Watts
Preamplifier Input Impedance50Ω typical, other values available upon request
Detector Input ConnectorsHN typical, other input connection types upon request
Remote Gain* (Flux to Thermal Matching)Fiber Optic Interface
*With use of Remote Gain Pendant
OutputsRatingsAccuracy
Pulse Level5 VDC TTL, 0 to 106 CPS±1% Full Scale
Log Count Rate Level0 to 10 VDC or 4 to 20 mA, 0.1 to 1E+6 CPS±2% Full Scale
LCR Rate (Doubling Time)0 to 10 VDC or 4 to 20 mA, -30 … ∞ … 3 seconds±1% Full Scale
Wide Range Log0 to 10 VDC or 4 to 20 mA, 10-8 to 200% Power±1% Full Scale
Wide Range Rate (Doubling Time)0 to 10 VDC or 4 to 20 mA, -30 … ∞ … 3 seconds1% Full Scale
Linear Power0 to 10 VDC or 4 to 20 mA, 0 to 200% Power1% Full Scale
Ion Chamber High Voltage100 to 1500 VDC, 10 W Max5% Full Scale
Front Panel Isolated BNC Multiple Signal Selections0 to 10 VDC1% Full Scale
LCR Level Trip 1*Form C Relay, 125VDC / 100mA Max
LCR Level Trip 2*
LCR Rate Trip 1*
LCR Rate Trip 2*
WR Level Trip 1*
WR Level Trip 2*
WR Rate Trip 1*
WR Rate Trip 2*
PR Level Trip 1*
PR Level Trip 2*
Channel-In-Test
Non-Op
Door Open
*Increasing or decreasing slope selectable.
EnclosureSpecification
Size (L x W x H)24″ x 16″ x 10″ (61 cm x 41 cm x 26 cm)
Weight50 lbs (23 kg)
MaterialStainless Steel
MountingWall Mount (4 Tabs)
SecurityLocking Door
Temperature Range32°F to 140°F (0°C to +60°C)
Relative Humidity10% to 95%, non-condensing
Qualification Safety Class 1E

Fully Analog Electronics
Safety Class 1E

  • Displays and operator controls are designed to comply with NUREG-0700.
  • Qualified for normal reactor operating conditions and post-accident monitoring (PAM), utilizing a guarded fission chamber (GFC).
  • The unit features a selectableinternal test function generator,a fiber optically interfacedremote gain input, and multipletrip functions for each fluxmeasurement output.
  • The unit also features twomulti-digit displays and fivevertical bar graphs for easyidentification of displayed variables.
Download CoreVision Overview